Laboratory R-407C โ refrigerant for research, teaching and analysis
Laboratory R-407C from REAL GAZ serves university and industrial laboratories that study vapour-compression cycles and glide behaviour.
As a zeotropic blend of R-32, R-125 and R-134a, it is a good teaching example of non-isothermal evaporation and condensation.
As a zeotropic blend of R-32, R-125 and R-134a, it is a good teaching example of non-isothermal evaporation and condensation.
Filling and testing reflect ISO 817 classification, ISO 17025 quality practice and EN 378 laboratory safety guidance for research and teaching use.
๐ญ Where R-407C for Laboratories Are Used
- โ๏ธ Thermodynamic research โ measuring glide, pressure drop and heat-transfer coefficients in test evaporators;
- ๐ฌ Student training โ practical courses on charging, superheat and subcooling with a modern HFC blend;
- ๐ฅ Lubricant studies โ evaluating POE oil miscibility and return on small circuits;
- ๐ Retrofit trials โ comparing R-22 and R-407C performance in the same compressor.
๐ก Why Choose REAL GAZ
- โ Reproducible results โ a stable blend keeps repeat experiments consistent;
- ๐งช Small formats โ cylinders sized for benches and teaching rigs, not only for field plant;
- ๐ฏ Safety clarity โ A1 classification and clear data sheets simplify risk assessments;
- ๐ Technical support โ our team explains handling, recovery and disposal expectations.
- ๐ Certificate of Analysis (CoA) โ supplied with every order.
๐ฌ Quality Control & Safety
- laboratory-grade moisture control;
- composition verification per lot;
- cylinder leak and pressure checks;
- labelling according to CLP and ADR.
Cylinders comply with ADR / UN transport rules and relevant EN/ISO standards.
๐ Technical and Handling Notes
Laboratory users should note that the temperature glide is about 7 K, so saturation temperatures differ between bubble and dew points and instrumentation must be set accordingly. Always charge from the liquid phase, ventilate rooms because the gas is heavier than air, and keep records of recovered refrigerant. Pressure at 20 ยฐC is near 11 bar, and thermal decomposition above flame temperatures can produce toxic and corrosive products.
A teaching laboratory benefits from a well-planned experiment series. Students can begin with a basic cycle on a bench refrigeration trainer, observe how bubble-point and dew-point temperatures differ, and then compare coefficient of performance at several evaporating temperatures. A second series may charge the circuit by weight and then by superheat, showing why zeotropic blends need liquid charging. Instruments such as pressure transducers, thermocouples and mass flow meters should be calibrated beforehand. We can supply small refrigerant quantities for course use and advise on a simple recovery and logbook routine that fits an academic environment. Laboratories planning publications should note the lot number of the cylinder in their method section, since this makes the refrigerant source traceable for later readers. Our team can also suggest suitable bench scales and recovery units for small refrigerant volumes.
โ๏ธ Trusted Gas Solutions
REAL GAZ supplies Laboratory R-407C to universities, technical colleges and research centres in Azerbaijan, Turkey, Georgia, Uzbekistan and the USA, with documentation suited to institutional procurement.
REAL GAZ โ dependable refrigerant for learning and discovery.