Technical Gas Freon โ refrigerant gases for cooling and HVAC service
Technical gas Freon is a common trade name for fluorocarbon refrigerants, and REAL GAZ supplies the modern equivalents such as R-134a, R-404A, R-407C and R-410A.
Each refrigerant has its own pressure curve, so we help you pick the product that suits your equipment.
Each refrigerant has its own pressure curve, so we help you pick the product that suits your equipment.
Products are designated under ISO 817, handled according to EN 378 and classed for transport under ADR, suitable for HVAC and refrigeration use.
Old CFC and HCFC refrigerants such as R-12 and R-22 are restricted or phased out in many markets, so we advise on retrofit options where an older system still runs. Always check the nameplate before topping up and never mix refrigerants in one system.
๐ญ Where Freon Refrigerants Are Used
- โ๏ธ Commercial refrigeration โ cold rooms and display cabinets rely on R-404A or R-134a;
- ๐ฌ Air conditioning โ split and chiller systems use R-410A and R-407C;
- ๐ฅ Automotive cooling โ R-134a serves many older vehicle systems;
- ๐ Industrial chillers โ process cooling in food and chemical plants.
๐ก Why Choose REAL GAZ
- โ Wide range โ several refrigerants from one supplier;
- ๐งช Clean product โ low moisture and non-condensables;
- ๐ฏ Retrofit advice โ guidance on replacing restricted gases;
- ๐ Sealed cylinders โ clearly labelled with UN number.
- ๐ Certificate of Analysis (CoA) โ supplied with every order.
๐ฌ Quality Control & Safety
- purity and moisture analysis;
- non-condensable gas checks;
- cylinder inspection and weighing;
- valve leak testing.
Cylinders and packaging comply with ADR / UN transport rules and relevant EN/ISO standards.
โ๏ธ Trusted Gas Solutions
REAL GAZ supplies technical gas Freon to service engineers and plants in Azerbaijan, Turkey, Georgia, Uzbekistan and the USA, supported by correct documentation.
Refrigerant handling should be left to trained technicians using recovery machines, manifold gauges and electronic leak detectors. Venting fluorinated gases to air is prohibited in many countries, so used gas should be recovered into dedicated cylinders. We accept enquiries about recovered gas, cylinder return and the records that regulators may ask you to keep.
The refrigerant market has shifted quickly, and many systems now use lower global warming alternatives such as R-448A, R-449A, R-452A and R-32. We help service companies compare options by capacity, glide, oil compatibility and flammability class, and we explain which gases need new components. Cylinders are supplied in sizes that depend on the product, always with labelling that shows the safety group and the global warming potential. Delivery can be coordinated with your service rounds, and the cylinder labels list the refrigerant name, safety classification and net weight clearly for inspectors.
REAL GAZ โ cooling gases you can rely on.