Precision Liquid Propane โ accurately specified propane for exact results
Precision Liquid Propane from REAL GAZ is propane whose purity and impurity profile are known and certified, so it can be used where measurement uncertainty must remain small.
Impurities such as ethane, isobutane and moisture are quantified at parts-per-million level and printed on the certificate supplied with each cylinder.
Impurities such as ethane, isobutane and moisture are quantified at parts-per-million level and printed on the certificate supplied with each cylinder.
Analysis relies on ISO 6143 calibration, ISO 6142-1 gravimetric preparation and ISO 17025 laboratory competence, while cylinder valves meet EN ISO 10297.
๐ญ Where Precision Propane Is Used
- ๐ Metrology and calibration โ acting as a reference gas when verifying hydrocarbon analysers and flow meters;
- ๐ซ๏ธ Emissions monitoring โ preparing calibration standards for total hydrocarbon analysers on stacks and engines;
- ๐ฅ Burner research โ delivering a fuel of known composition for combustion efficiency measurements;
- ๐ง Sensor development โ checking the response of catalytic bead and infrared propane sensors during manufacture.
๐ก Why Choose REAL GAZ
- ๐ฏ Certified composition โ each cylinder carries stated values with expanded uncertainty;
- โ๏ธ Gravimetric basis โ masses are weighed on calibrated balances to give traceable concentrations;
- ๐งช Stable cylinders โ internal surface treatment reduces adsorption losses in low-concentration mixtures;
- ๐ Defined shelf life โ the certificate states a validity period so your quality system can schedule replacement;
- ๐ Certificate of Analysis (CoA) โ supplied with every order.
๐ฆ Handling & Supply Notes
Precision work needs careful cylinder handling. Allow a cylinder to equilibrate to room temperature before use, because composition near the liquid surface can differ slightly in cold conditions. Use a regulator with stainless steel diaphragm and purge the connection several times before sampling, which removes trapped air and moisture. Record the cylinder number, date of first use and remaining pressure, and replace cylinders when they reach the minimum pressure stated on the certificate, since uncertainty may increase as the contents are used. Where regulators or auditors review your measurements, keep the certificate, the pressure log and the calibration records together. If a cylinder falls outside its stated validity, we can supply a replacement quickly, so that your measurement programme continues without gaps in traceability.
๐ฌ Quality Control & Safety
- gravimetric preparation on calibrated balances;
- analytical verification against reference standards;
- impurity screening by gas chromatography;
- leak testing and pressure integrity checks.
Cylinders comply with ADR / UN transport rules and relevant EN/ISO standards.
โ๏ธ Trusted Gas Solutions
Calibration laboratories and process industries in Azerbaijan, Turkey, Georgia, Uzbekistan and the USA depend on REAL GAZ when precision liquid propane is called for in their procedures. Tell us the uncertainty you need and we will confirm which grade and certificate level can meet it.
REAL GAZ โ precision you can verify, number by number.