Laboratory Oxygen Safety Arrestor โ controlled oxygen supply for research and analysis
A Laboratory Oxygen Safety Arrestor from REAL GAZ is installed on oxygen lines that feed burners, furnaces, combustion analysers and glassworking torches.
Flow rates are small, but the need for cleanliness and reliable shut-off is high.
Flow rates are small, but the need for cleanliness and reliable shut-off is high.
In laboratories, oxygen lines are often shared with fuel gases such as hydrogen or natural gas. A backflow of fuel into the oxygen line could create a hazardous mixture, so a non-return valve with flame arrest is vital at every point of use. Our laboratory units are compact, easy to mount on benches and supplied cleaned for oxygen so that sensitive instruments are not contaminated.
Laboratories should label every gas line at the cylinder and at the point of use, keep cylinders chained in a ventilated storage area, and use regulators dedicated to oxygen. Where oxygen enrichment is possible, install an oxygen monitor, since air with more than 23.5 percent oxygen greatly increases fire risk.
Typical laboratory flow rates are measured in millilitres or a few litres per minute, so the arrestor must create very little pressure drop. Our compact units are chosen for this duty, and can be supplied with stainless steel tubing and push-fit or compression fittings for neat bench installation. We can supply complete gas panels for laboratories, including cylinder regulators, line filters, arrestors and labelled outlets, installed to suit the room layout and safety review. Calibration gases, zero air and high-purity oxygen for the same laboratory can be ordered together, giving one delivery schedule and one point of contact for all bench gases.
REAL GAZ supplies the device in line with EN ISO 5175-1, EN ISO 2503 and ISO 15001, for research and analytical settings.
๐ญ Where Laboratory Oxygen Arrestors Are Used
- ๐ฌ Combustion analysis โ elemental analysers receive protected oxygen at stable low flow;
- ๐ฅ Furnaces and ovens โ tube furnaces with oxygen atmospheres are protected from backflow;
- ๐ง Glassworking โ bench torches burn fuel and oxygen with arrestors on both lines;
- ๐ Teaching laboratories โ students handle gas lines with built-in safeguards.
๐ก Why Choose REAL GAZ
- โ Low-flow design โ suited to analytical gas flows;
- ๐งช Clean supply โ oxygen-clean parts avoid contamination;
- ๐ฏ Compact โ fits benches, fume cupboards and instrument racks;
- ๐ Audit ready โ marking and documentation support safety reviews;
- ๐ Certificate of Analysis (CoA) โ supplied with every order.
๐ฌ Quality Control & Safety
- oxygen-service cleaning;
- leak test with helium or inert gas where required;
- check valve function test;
- sealed packing.
Products comply with ADR / UN transport rules and relevant EN/ISO standards.
โ๏ธ Trusted Gas Solutions
REAL GAZ supplies the Laboratory Oxygen Safety Arrestor with regulators, tubing and cylinders to universities and research centres in Azerbaijan, Turkey, Georgia, Uzbekistan and the USA.
REAL GAZ โ safe oxygen at the bench.