Go to content

Buy Heliox Gas Mixture - REAL GAZ

Home          About us          Projects           Services           Products          Contacts
AZ | TR | RU | EN | GE
Industrial R-407C Gas โ€” reliable R-22 replacement for plant and commercial systems
Industrial R-407C Gas from REAL GAZ is a zeotropic HFC blend of R-32, R-125 and R-134a in a 23/25/52 mass ratio, widely used to retrofit and service air-conditioning plant that once ran on R-22.
It has zero ozone depletion potential and a safety classification of A1.
Supply follows ISO 817 classification, EN 378 system safety and AHRI 700 purity levels, with filling controlled for industrial maintenance contractors.

๐Ÿญ Where Industrial R-407C Are Used
  • โš™๏ธ Chiller plant โ€” topping up and retrofitting water chillers serving factories, hotels and hospitals;
  • ๐Ÿ”ฌ Rooftop packaged units โ€” servicing large commercial air-handling equipment in warehouses and shopping centres;
  • ๐Ÿฅ Process cooling โ€” charging heat-exchange circuits on plastics, food and printing lines;
  • ๐Ÿš€ Heat pump service โ€” maintaining medium-temperature heat pumps that were designed around R-22 pressures.

๐Ÿ’ก Why Choose REAL GAZ
  • โœ… Close to R-22 pressures โ€” existing compressors and controls often need only a change of oil and filter drier;
  • ๐Ÿงช Zero ODP โ€” suitable where ozone-safe refrigerants are required by policy or tender;
  • ๐ŸŽฏ Bulk ready โ€” cylinder sizes for single service calls and for contractors with a regular workload;
  • ๐Ÿ”’ Consistent blend โ€” tight composition control keeps capacity and glide predictable on site.
  • ๐Ÿ“„ Certificate of Analysis (CoA) โ€” supplied with every order.

๐Ÿ”ฌ Quality Control & Safety
  • controlled liquid transfer from tank to cylinder;
  • blend composition check by gas chromatography;
  • water and acidity limits verified;
  • cylinder pressure test and valve inspection.
Cylinders comply with ADR / UN transport rules and relevant EN/ISO standards.

๐Ÿ“˜ Technical and Handling Notes
Because R-407C has a temperature glide of around 7 K, it must always be charged in the liquid phase so the composition in the system is not changed. Technicians should use POE lubricant, check the evaporator superheat after charging and record the charge weight for F-gas logbooks. Cylinders are normally supplied in 11.3 kg, 13.6 kg and larger refillable sizes, and should be kept upright and out of direct sun.
Retrofit planning deserves care. Before converting an R-22 plant, drain the mineral oil and replace it with POE, change the filter drier, and check that the expansion valve is rated for the new blend. Seals and gaskets should be inspected for compatibility, and the system should be evacuated below 500 microns and held to prove tightness. After charging, record suction and discharge pressures, superheat and subcooling at several loads. Facilities with large charges should register the refrigerant quantity, schedule leak checks according to local regulation, and use fixed detectors where the plant room is below ground. Where a site holds several chillers, we suggest a single logbook per machine so charge history and leak repairs stay visible to auditors and to the next engineer.

โš™๏ธ Trusted Gas Solutions
REAL GAZ delivers Industrial R-407C Gas to contractors, facility managers and OEM service teams across Azerbaijan, Turkey, Georgia, Uzbekistan and the USA, with guidance on charging practice and safe cylinder handling.
REAL GAZ โ€” steady cooling capacity for working plant.
You can send your positive/negative feedback on our products and services to the following email: [email protected]

ยฉ REALGAZ - All rights reserved.
Site developed by AYVUS.COM
Back to content