High Purity Calibration Gas for laboratory โ low-impurity standards for sensitive laboratory methods
High purity calibration gas for laboratory work from REAL GAZ is chosen for methods in which a trace impurity can ruin a result. The calibration standard and the balance gas are both selected for low contaminant levels, so that the measured response belongs to the analyte and not to the cylinder.
Grades run from 5.0 (99.999%) to 6.0 (99.9999%) for carrier and zero gases.
Grades run from 5.0 (99.999%) to 6.0 (99.9999%) for carrier and zero gases.
Gas chromatographs, ICP and mass spectrometers each place their own demands on supply. Moisture, oxygen and total hydrocarbons are the usual troublemakers, so we report them for each lot. We recommend stainless steel regulators with metal diaphragms and clean tubing, because even excellent gas can be contaminated by a poor delivery line. Standards are available at ppm and ppb levels in nitrogen, helium or argon. Delivery hardware deserves attention. Use stainless steel or properly cleaned copper tubing, purge the regulator several times before opening the cylinder to the instrument, and fit gas purifiers or moisture traps where the method calls for them. Avoid plastic tubing for oxygen-sensitive work, since it allows air to diffuse in. For long unattended runs, an automatic changeover manifold prevents a baseline disturbance when one cylinder empties, and we can specify one for your bench.
REAL GAZ supplies this product according to ISO 6142, ISO 6143 and ISO 17025 practice, suitable for analytical and research laboratories.
๐ญ Where High Purity Calibration Gas Is Used
- ๐ฌ Gas chromatography โ calibration standards and carrier gases that keep baselines flat and peaks quantifiable;
- ๐งฌ Mass spectrometry โ clean collision and nebuliser gases together with tuning standards;
- ๐ซ๏ธ Air and trace analysis โ ppb-level standards for ambient monitoring and indoor air studies;
- ๐งซ Pharmaceutical quality control โ reference gases for residual solvent and headspace methods.
๐ก Why Choose REAL GAZ
- โ Low impurity levels โ moisture, oxygen and hydrocarbon content are controlled for sensitive detectors;
- ๐งช Matched balance gas โ calibration mixtures use a balance gas that is purer than the lowest range of your method;
- ๐ฏ Lot reporting โ impurity data per lot supports method validation files;
- ๐ Clean cylinder treatment โ internal surfaces are prepared to limit adsorption of trace components;
- ๐ Certificate of Analysis (CoA) โ supplied with every cylinder, stating purity grade and measured impurities.
๐ฌ Quality Control & Safety
- multi-stage purification of the source gas;
- cylinder evacuation and conditioning;
- trace moisture and oxygen analysis;
- leak testing and pressure integrity checks.
Cylinders comply with ADR / UN transport rules and relevant EN/ISO standards.
โ๏ธ Trusted Gas Solutions
REAL GAZ provides high purity calibration gas for laboratory customers in Azerbaijan, Turkey, Georgia, Uzbekistan and the USA, from university departments to accredited testing houses. Tell us the method and the detection limit, and we will recommend a grade and cylinder size.
REAL GAZ โ purity you can measure.