Go to content

Buy Heliox Gas Mixture - REAL GAZ

Home          About us          Projects           Services           Products          Contacts
AZ | TR | RU | EN | GE
High Pressure R-407C โ€” managing pressure safely in refrigeration systems
High Pressure R-407C is a topic every refrigeration technician meets daily: the blend condenses at pressures similar to R-22, roughly 11 bar at 20 ยฐC and above 25 bar at 55 ยฐC.
REAL GAZ supplies cylinders and guidance suited to those pressures.
Equipment and cylinders align with PED 2014/68/EU, EN 378 and ISO 9809, with test records for pressure-rated service equipment.

๐Ÿญ Where R-407C Are Used
  • โš™๏ธ Condensing units โ€” verifying head pressure against design limits during commissioning;
  • ๐Ÿ”ฌ Pressure testing โ€” separate nitrogen tests complement refrigerant leak detection;
  • ๐Ÿฅ Hot-climate cooling โ€” operating plant in summer ambient conditions where condensing pressure climbs;
  • ๐Ÿš€ Heat pump duty โ€” running medium-temperature systems with elevated discharge pressure.

๐Ÿ’ก Why Choose REAL GAZ
  • โœ… Pressure-tested vessels โ€” cylinders hold current periodic inspection marks;
  • ๐Ÿงช Gauge advice โ€” we recommend manifold sets rated well above R-407C working pressure;
  • ๐ŸŽฏ Reliable valves โ€” outlets chosen for leak-free sealing at working pressure;
  • ๐Ÿ”’ Safety knowledge โ€” clear notes on relief devices, overfill and heat exposure.
  • ๐Ÿ“„ Certificate of Analysis (CoA) โ€” supplied with every order.

๐Ÿ”ฌ Quality Control & Safety
  • hydrostatic testing of vessels;
  • overfill prevention by weighing;
  • valve pressure integrity check;
  • gas quality verification before release.
Cylinders comply with ADR / UN transport rules and relevant EN/ISO standards.

๐Ÿ“˜ Technical and Handling Notes
Pressure is not the only concern: the blend is a liquefied gas, so cylinder pressure depends on temperature, not on remaining quantity. A cylinder in a hot vehicle can reach pressures near 30 bar, which is why cylinders must never be filled above the permitted fill ratio. Use pressure regulators and hoses rated for HFC service, never use air for leak testing, and relieve pressure slowly through the recovery unit.
Understanding the pressure-temperature relationship helps avoid mistakes. For a zeotropic blend there are two pressures for a given temperature, one at the bubble point and one at the dew point, so a technician must read the correct column of the pressure-temperature chart. Approximate saturation pressures are 11 bar at 20 ยฐC, 18 bar at 40 ยฐC and 27 bar at 60 ยฐC for the liquid. If the discharge pressure of a plant climbs above design, check for dirty condensers, failed fans and non-condensable gases before adding or removing refrigerant. Always fit high-pressure cut-outs and test them periodically. Equipment owners should also schedule inspection of pressure relief valves and safety switches, since these devices protect both people and compressors. Our team is happy to review your gauge range and hose ratings before you start work.

โš™๏ธ Trusted Gas Solutions
REAL GAZ provides High Pressure R-407C cylinders and technical guidance to service engineers in Azerbaijan, Turkey, Georgia, Uzbekistan and the USA, with attention to correct fill ratios and safe handling.
REAL GAZ โ€” pressure managed, systems protected.
You can send your positive/negative feedback on our products and services to the following email: [email protected]

ยฉ REALGAZ - All rights reserved.
Site developed by AYVUS.COM
Back to content