Freon R-407C Gas Cylinder โ ready-to-use refrigerant packaging for service teams
A Freon R-407C Gas Cylinder from REAL GAZ combines the refrigerant and its packaging in one controlled product, filled to a declared mass and sealed for transport.
The contents are the 23/25/52 HFC blend, with zero ozone depletion potential.
The contents are the 23/25/52 HFC blend, with zero ozone depletion potential.
Cylinders follow EN 1964, EN ISO 11114 material compatibility and ADR / UN marking, and contents conform to ISO 817 for service use.
๐ญ Where Freon R-407C Cylinders Are Used
- โ๏ธ Emergency repair โ carrying a single cylinder to a failed rooftop unit or cold room;
- ๐ฌ Planned maintenance โ charging chillers during seasonal inspections;
- ๐ฅ Installation โ adding charge to long pipe runs on split systems;
- ๐ Conversion work โ recharging after an R-22 retrofit with fresh oil and driers.
๐ก Why Choose REAL GAZ
- โ Declared fill mass โ know exactly how much refrigerant you are carrying;
- ๐งช Robust packaging โ valves protected by caps, with colour-coded identification;
- ๐ฏ Right sizes โ pack sizes chosen for van loading and for safe manual handling;
- ๐ Fresh product โ dated fills keep refrigerant stock moving and avoids ageing inventory.
- ๐ Certificate of Analysis (CoA) โ supplied with every order.
๐ฌ Quality Control & Safety
- cylinder condition and thread inspection;
- evacuation to deep vacuum before filling;
- weighed liquid fill;
- final weight and leak verification.
Cylinders comply with ADR / UN transport rules and relevant EN/ISO standards.
๐ Technical and Handling Notes
Do not store a partly used cylinder near heat, and never try to refill a disposable one. If liquid must be withdrawn, use a service hose rated for pressure and a manifold that can control flow. Check the valve for oil traces, which can indicate a slow leak. Pressure at 20 ยฐC is approximately 11 bar, and the cylinder must be secured upright during transport so the relief device does not discharge liquid.
Looking after a cylinder in daily work is simple but important. Keep the valve closed when not in use, and fit the protective cap after each job. Wipe the outlet clean before connecting a hose, and replace worn sealing washers rather than overtightening. Do not leave cylinders in a closed vehicle at midday, because the temperature inside can exceed 60 ยฐC. Do not roll or drop cylinders; use a trolley and secure them with a chain or strap. At the end of the day, return unused vessels to a cool, ventilated store away from ignition sources. Cylinders of different sizes are marked clearly, so teams can pick the right vessel quickly from the stockroom without reading small print.
โ๏ธ Trusted Gas Solutions
REAL GAZ delivers every Freon R-407C Gas Cylinder with batch paperwork to engineers and wholesalers in Azerbaijan, Turkey, Georgia, Uzbekistan and the USA, and can supply recovery cylinders as well.
REAL GAZ โ the full package for a safe refrigerant charge.