Cylinder Oxygen Regulator for laboratory โ€” steady cylinder pressure for analytical work
A Cylinder Oxygen Regulator for laboratory bench must deliver smooth, low-noise pressure to instruments that are sensitive to supply variations. REAL GAZ offers regulators sized for standard laboratory cylinders.
Parts in contact with the gas are cleaned for oxygen and tested for tightness.
Selection follows ISO 5145 cylinder outlet practice, EN ISO 10524 principles and ISO 17025 laboratory expectations, for analytical and research teams.

๐Ÿญ Where Laboratory Oxygen Regulators Are Used
  • โš™๏ธ Combustion analysis โ€” elemental analysers and calorimeters burn samples in oxygen, so a stable supply protects result repeatability;
  • ๐Ÿ”ฌ Respirometry and biology โ€” cell culture and environmental studies use controlled oxygen atmospheres in incubators and test chambers;
  • ๐Ÿฅ Materials testing โ€” oxidation and thermal studies need a measured oxygen feed into tube furnaces and small test cells;
  • ๐Ÿš€ Teaching laboratories โ€” universities use compact cylinders with simple regulators for supervised student demonstrations.

๐Ÿ’ก Why Choose REAL GAZ
  • โœ… Fine adjustment โ€” smooth control lets analysts hold the delivery pressure an instrument manual asks for;
  • ๐Ÿงช Compact formats โ€” regulators suit benchtop cylinders and wall-mounted racks where space is limited;
  • ๐ŸŽฏ Clean wetted parts โ€” low particulate assembly reduces contamination of sensitive analytical circuits;
  • ๐Ÿ”’ Documented supply โ€” product data helps laboratories keep their quality files complete and ready for audit;
  • ๐Ÿ“„ Certificate of Analysis (CoA) โ€” supplied with every order.

๐Ÿ”ฌ Quality Control & Safety
  • precision cleaning and drying;
  • helium leak or bubble testing of joints;
  • outlet stability verification;
  • visual inspection of seats and gauges.
Cylinders comply with ADR / UN transport rules and relevant EN/ISO standards.

๐Ÿ“ฆ Fitting and Handling Notes
Fit the regulator with a clean, correct washer and tighten only with the proper spanner. Purge the connecting line before first use. Chain cylinders upright, keep them away from solvents and heat, and close the valve at the end of each working day.
Typical laboratory cylinders are filled to around 200 bar, so the inlet gauge range must exceed that value, while the outlet gauge should read in a band close to the instrument requirement for good resolution. Ask us to match both ranges to the instrument manual, and to suggest a suitable shut-off valve and non-return device downstream. Where several instruments share one supply, a small manifold with individual regulators keeps each line independent and simplifies maintenance.

โš™๏ธ Trusted Gas Solutions
REAL GAZ supports universities, quality laboratories and research institutes in Azerbaijan, Turkey, Georgia, Uzbekistan and the USA that need a cylinder oxygen regulator for laboratory work. We can also supply matching cylinders, tubing and gas purifiers for the whole bench.
REAL GAZ โ€” a steady supply behind every reading.
You can send your positive/negative feedback on our products and services to the following email: [email protected]

ยฉ REALGAZ - All rights reserved.
Site developed by AYVUS.COM
Back to content