Go to content

Buy Heliox Gas Mixture - REAL GAZ

Home          About us          Projects           Services           Products          Contacts
AZ | TR | RU | EN | GE
Calibration Gas Mixture for analyzers โ€” matched standards for online and bench analysers
A calibration gas mixture for analyzers must match the sensor technology as well as the concentration. REAL GAZ supplies span and zero gases chosen for infrared, electrochemical, paramagnetic, flame ionisation and chromatographic instruments.
The goal is a response that tells you how the analyser behaves, free from interference introduced by the standard.
Manufacturers often state a calibration range, such as 0 to 100 ppm or 0 to 25% volume, and recommend a span near 80% of it. We can blend accordingly, with a balance gas that does not disturb the measuring principle. For NDIR instruments we avoid cross-sensitive components; for flame detectors we supply hydrocarbon-free zero air; and for chromatographs we supply multi-component standards covering the full retention window. Good calibration practice includes a zero point, a span point and, for non-linear instruments, one or more intermediate levels. Allow the analyser to stabilise on each gas, record the reading and the cylinder number, and compare the result with the previous calibration to spot drift. Dynamic dilution systems can generate intermediate levels from one parent cylinder, and we can supply the parent mixture and advise on suitable mass flow controllers for the task.
REAL GAZ supplies this product according to ISO 6142, ISO 6143 and ISO 17025 practice, suitable for inline and bench analysers.

๐Ÿญ Where Analyser Calibration Mixtures Are Used
  • ๐Ÿ“ก Continuous emission monitoring โ€” NOx, SOโ‚‚, CO and COโ‚‚ standards for stack analysers under permit conditions;
  • ๐Ÿงด Gas chromatographs โ€” multi-component hydrocarbon or permanent gas standards for quantitative calibration;
  • ๐ŸŒก๏ธ Combustion analysers โ€” oxygen and carbon monoxide mixtures for boiler and burner tuning;
  • ๐Ÿฅฌ Storage atmosphere control โ€” oxygen and carbon dioxide standards for controlled atmosphere stores and ripening rooms.

๐Ÿ’ก Why Choose REAL GAZ
  • โœ… Technology-matched โ€” balance gas and components are chosen to avoid sensor interference;
  • ๐Ÿงช Span and zero sets โ€” one order covers a full calibration cycle;
  • ๐ŸŽฏ Range guidance โ€” we suggest concentrations from the analyser's range and alarm points;
  • ๐Ÿ”’ Stable fills โ€” suitable cylinders and valves preserve concentration during storage;
  • ๐Ÿ“„ Certificate of Analysis (CoA) โ€” with certified concentrations, uncertainty and expiry date.

๐Ÿ”ฌ Quality Control & Safety
  • selection of balance gas and cylinder material;
  • gravimetric blending of target concentrations;
  • verification on reference analysers;
  • leak and pressure testing before release.
Cylinders comply with ADR / UN transport rules and relevant EN/ISO standards.

โš™๏ธ Trusted Gas Solutions
REAL GAZ provides calibration gas mixture for analyzers to operators in Azerbaijan, Turkey, Georgia, Uzbekistan and the USA. Share the analyser model and measuring range, and our specialists will confirm the mixture and cylinder format.
REAL GAZ โ€” standards that suit the instrument.
You can send your positive/negative feedback on our products and services to the following email: [email protected]

ยฉ REALGAZ - All rights reserved.
Site developed by AYVUS.COM
Back to content